Meter Manual

Index of Drawings:

* indicates "NOT FOR NEW CONSTRUCTION"

(Please note: The online Meter Specification Manual is in pdf formatted files, so Acrobat Reader is required to open them. You may download a free copy of Acrobat Reader from Adobe's web site.

Chapter 1

1.07.1 SINGLE PHASE SOCKET WIRING
1.07.2 SINGLE PHASE INSTRUMENT TRANSFORMERS (CT’S & PT’S)
1.07.3 THREE PHASE, 4 WIRE, WYE SOCKETS & CT’S
1.07.4 THREE PHASE, 3 WIRE, CLOSED DELTA SOCKETS
1.07.5 THREE PHASE, 3 WIRE, CLOSED DELTA (CT’S & PT’S)
1.07.6 THREE PHASE, 4 WIRE, CLOSED DELTA SOCKETS & CT’S
1.07.7 THREE PHASE, 3 WIRE, OPEN DELTA SOCKETS
1.07.8 THREE PHASE, 4 WIRE, OPEN DELTA SOCKETS & CT’S
1.07.9 * 6 WIRE TOTALIZED SERVICE (NOT FOR NEW CONSTRUCTION)
* 5 WIRE TOTALIZED SERVICE (NOT FOR NEW CONSTRUCTION)
1.07.10 2 CKT TOTALIZED 3PH, 4W WYE (120/208V, 277/480V)
1.07.11 2 CKT TOTALIZED 3PH, 4W DELTA (240V, 480V)
1.07.12 PRIMARY METERING SINGLE PHASE (480V, 2400V)
PRIMARY METERING 3 PH, 4W (13,800V)
1.07.13 PRIMARY METERING 3 PH, 3W (4160V)

Chapter 4

Socket Metering

4.02.1 120V 2W (1 KW MAXIMUM.)
4.02.2 120/240V 1PH 3W 150A OVERHEAD
4.02.3 120/240V 1PH 3W 200A OVERHEAD
4.02.4 120/240V 1PH 3W 200A UNDERGROUND
4.02.6 120/240V 1PH 3W 320A OVERHEAD
4.02.7 120/240V 1PH 3W 320A UNDERGROUND
4.02.8 * 240v 1PH 2W & 120/240V 1PH 3W TOTALIZED
4.02.9 240/480V 1PH 3W 200A OVERHEAD
4.02.10 240V 3PH 3W or 480V 3PH 3W 200A OVERHEAD
4.02.11 480V 3PH 3W 200A OVERHEAD
4.02.12 120/240V 3PH 4W OVERHEAD
4.02.13 120/208V 3PH 4W or 277/480V 3PH 4W 200A OVERHEAD
4.02.15 120/208V 3PH 4W 320A OVERHEAD or UNDERGROUND

4.05.1 OVERHEAD SERVICE, 2 TO 6 METERS
4.05.2 UNDERGROUND SERVICE, 2 TO 6 METERS
4.05.3 UNDERGROUND SERVICE, 2 TO 6 METERS

Transformer Metering

4.06.1 DIAGRAM I, II, & III (6 MAIN RULE)
4.06.2 * 120/240V 1PH 3W "A"-base CT
4.06.3 120/240V 1PH 3W socket CT
4.06.4 * 120/240V 1PH 3W & 240V 3Ph 3W 6W totalized "A"-base CT
4.06.5 * 120/240V 1Ph 3W & 240V 3Ph 3W 6W totalized "A"-base CT kW
4.06.6 * 120/240V 1Ph 3W & 240V 3Ph 3W 6W totalized "A"-base CT kW, kVA
4.06.7 * 120/240V 1Ph 3W & 240V 3Ph 3W 6W totalized "A"-base CT kW
4.06.8 * 240V 3Ph 3W delta "A"-base CT
4.06.9 240V 3Ph 3W delta socket CT
4.06.10 * 3Ph 3W delta "A"-base CT (240V, 480V, 2400V, or 13,800V) kW, kVA
4.06.11 * 3Ph 3W delta socket CT (240V, 480V, 2400V, or 13,800V) kW, kVA
4.06.12 * 3Ph 3W delta "A"-base CT (480V, 2400V, or 13,800V) kW, kVA
4.06.13 * 120/240/240V 3Ph 4W "A"-base CT
4.06.14 * 3Ph 4W "A"-base CT (120/208V, 277/480V, 2400/4160V, or 7960/13,800V)
4.06.15 3Ph 4W socket CT (120/208V, 277/480V, 2400/4160V, or 7960/13,800V)
4.06.16 * 3Ph 4W "A"-base CT (120/208V, 277/480V, 2400/4160V, or 7960/13,800V) kW, kVA
4.06.17 * 3Ph 4W socket CT (120/208V, 277/480V, 2400/4160V, or 7960/13,800V) kW, kVA
4.06.18 * 3Ph 4W "A"-base CT (120/208V, 277/480V, 2400/4160V, or 7960/13,800V) kW, kVA 2 circuit totalized

Chapter 5

5.07.1 OVERHEAD TEMPORARY SERVICE POLE
5.07.2 OVERHEAD TEMPORARY SERVICE POLE
5.55 UNDERGROUND TEMPORARY SERVICE POLE

Chapter 6

6.08.4 OVERHEAD RESIDENTIAL SERVICE: DUPLEX SOCKET-150AMP
6.08.3 OVERHEAD RESIDENTIAL SERVICE: THREE-PLEX SOCKET-150A
6.08.2 OVERHEAD RESIDENTIAL SERVICE: DUPLEX SOCKET-200AMP
6.08.1 OVERHEAD RESIDENTIAL SERVICE: MAST INSTALLATION, SOCKET
6.09 OVERHEAD RESIDENTIAL SERVICE: WALL INSTALLATION, SOCKET
6.10 OVERHEAD RESIDENTIAL SERVICE & GENERAL SERVICE: INSTRUMENT TRANSFORMER METER

Chapter 7

7.02.1 CUSTOMER DUCT UNDER RETAINING WALLS
7.02.2 CONDUIT SLEEVE DETAIL
7.04.1 UNDERGROUND RESIDENTIAL SOCKET ON A CANTILEVER
7.04.2 UNDERGROUND RESIDENTIAL SOCKET UNDER A CANTILEVER
7.05.1 UNDERGROUND RESIDENTIAL SERVICE: 200 AMP SOCKET
7.05.2 UNDERGROUND RESIDENTIAL SERVICE: 320 AMP SOCKET
7.05.3 UNDERGROUND RESIDENTIAL SERVICE: DUPLEX SOCKET
7.06 UNDERGRD RESIDENTIAL SVCE: FREESTANDING METER SUPPORT
7.07 UNDERGRD RESIDENTIAL SVCE: CURRENT TRANSFORMER (CT)

Chapter 8

8.04.1 UNDERGROUND SOCKET, GENERAL SERVICE: 200 AMP
8.04.2 UNDERGROUND SOCKET, GENERAL SERVICE: 320 AMP
8.05 UNDERGROUND SOCKET, GENERAL SERVICE: FREESTANDING METER SUPPORT
8.06 UNDERGROUND, GENERAL SERVICE: INSTRUMENT TRANSFORMER METER
8.08.1 SLAB DETAIL, 1 Ph PDMT TRANSFORMER. LOPRO (15 TO 167 kVA)
8.08.2 SLAB DETAIL, 1 Ph PDMT TRANSFORMER, CONV. (25 TO 167 kVA)
8.08.4 SLAB DETAIL, 3 Ph PDMT TRANSFORMER, (75 TO 500 kVA)
8.08.5 SLAB DETAIL, 3 Ph PDMT TRANSFORMER, (750 TO 1000 kVA)
8.08.6 SLAB DETAIL, 3 Ph PDMT TRANSFORMER, (1500, 2000, & 2500 kVA)
8.08.7 CUSTOMER’S CABLE PULL BOX INSTALLATION
8.08.8 METERING EQUIPMENT ON 3 Ph TRANSFORMER (AEOT)
8.08.9 6’x6’ PRECAST MANHOLE
8.09.1 TRANSFORMER AND SECONDARY CABINET SLAB DETAIL (750 & 1000 KVA)
8.09.2 TRANSFORMER AND SECONDARY CABINET SLAB DETAIL (1500, 2000 & 2500 KVA)

Chapter 9

9.06.1 MOBILE HOME PARK SERVICE, UNDERGROUND, SINGLE METER
9.06.2 MOBILE HOME PARK SERVICE, UNDERGROUND, DOUBLE METER
9.07 MOBILE HOME PARK SERVICE, OVERHEAD POLE

Chapter 11

11.08 DETENT METERING

Chapter 12

12.02.1 NETWORK CABLE LIMITER INSTALLATION, 208V
12.02.2 NETWORK CABLE LIMITER INSTALLATION, 480V


Back to the Meter Specification Manual Table of Contents